Biometric monitoring and access control system “BioSmart”
 Purpose

Access control system BioSmart allows an enterprise to organize effective monitoring and access control system. Access control system BioSmart meets contemporary requirements made to systems with high security level, control over attendance and labor discipline, integration with every existing access control device.

Access control system BioSmart principle of operation is based on technology of person identification by fingerprints scanning. Use of latest development works in biometric provides high reliability of the system featuring easy installation and user friendly operations.

Download video (Rar, size: 4,1 Мб)

Main functions

Access monitoring and control:

  • person identification by fingerprint scanning;
  • access only for registered employees and visitors;
  • control of execution units (doors, turnstiles, barriers);
  • alarm signal initiation in the attempt of unapproved access;
  • events journaling;
  • access differentiation according to time zones (64 time groups, 5 ranges for each day, 32 holidays).

Absentee management:

  • automated employees' coming and leaving time registration;
  • conducting of working time table;
  • generation of attendance, absence, being late or early leaving reports;
  • generation and maintenance of employees database (electronic filing);
  • data import to Microsoft Excel and other programs.

Safeguarding:

  • integration with any existing monitoring system of access control and security alarm system;
  • input possibility of "alarming finger" regime.

Benefits

Thanks to the method of dactyloscopic person identification access control system BioSmart has a number of benefits in front of traditional access control systems using magnetic cards and electronic keys:

  • unapproved use of keys is excluded;
  • high degree of imitation protection is provided;
  • necessity of obligatory keys carrying disappears;
  • influence of human factor is excluded (key loss or damage, forgetfulness, keys transfer to the third parties, etc.);
  • there are no expenses for new keys manufacturing, replacement or restoration of the existing.

Distinctive feature of access control system BioSmart is use of capacitive fingerprints scanners instead of traditional optical. As a result the system possesses higher technical characteristics:

  • digital fingerprint image of high quality;
  • the fastest scanning time, no more than 1 second;
  • patented hardware fake protection.

Access control system BioSmart structure chart

Access control system BioSmart is a network distributed system with users' access rights demarcation. It can be extended in case of need and is opened for integration with other devices. Networking is organized with the use of RS485 interface, existing Ethernet leased circuits or GSM format cellular networks. BioSmart controllers are united in RS485 main line (up to 255 pcs.). For PC connection USBRS485, LANRS485, GPRSRS485 interface converters are used.

Структурная схема СКУД BioSmart 


Access control system BioSmart principle of operation

Registration of users is carried out with the help of BioSmart Studio Software and control reader plugged-in through the USB port of a personal computer. It is possible to register about 10 fingerprints for each user, thus only mathematic templates of fingerprints are putted in a database that makes impossible a return reconstruction of fingerprints' graphic presentation. Further the user is given rights of access to the particular points of pass, thus encoded templates of fingerprints are transmitted by circuits to the BioSmart controller and further are kept there aside from a computer.

When a user applies a finger to the scanner of the BioSmart controller, a search of registered templates in the controller database is occurred. At a successful identification the BioSmart controller generate a signal to relay control unit via secure digital circuit which is by-turn switches on execution units (electromagnetic locks, turnstiles and etc.).Thus the possibility of an unauthorized access by means of wire bridging or control signal imitation is excluded. At a successful identification appropriate information is registered in a log book. In case of unsuccessful identification or prohibition of pass information is also registered.

BioSmart Controller can work together with external sensors. For this purpose two quantized inputs are provided on the control unit. The first quantized input is used to connect remote exit button. The second quantized input can be used to connect door opening sensor, turnstile sensor and fire alarm. All events on external sensors are also registered in a log book.

THE BASIC COMPONENTS OF Access control system BioSmart

BioSmart biometric controller

Purpose of use

BioSmart biometric controller is an electronics module designed for fingerprints identification. The controller has non-volatile memory for 9000 fingerprints, 12800 events, 64 time groups, 5 ranges for each day and 32 holidays. All events are registered in the controller in chronological order with precise time indication. The controller is equipped with a power indicator and a sound buzzer so as to inform user about identification results.

Main technical characteristics

Fingerprint capacity
9000
Events capacity

12800

Time zones

64 time groups, 5 ranges for each day, 32 holidays

Fingerprint scanner

capacitive

False FAR access probability
not more than 0.0001%
False FAR access failure probability
not more than 0.001%
Identification speed 1:1000
not more than 1 sec
Size of the fingerprint data
256 ~ 384 byte
Communications interface
RS485, 115200 b/sec
Wiegand-26 interface
1 input, 1 output
Non-volatile memory for the log book
Data encryption key
256 bit AES
Power supply, max. consumption
12 V DC, 250 mA
Dimensions (L x W x H)
175х75х54
Operating temperature
-40°С ~ +50 °С
Sensor of case breaking

yes

Fingerprint scanner for personal computer

 

Purpose of use

The scanner corresponds to a module which captures fingerprint image and transfers it to a personal computer. Unique technology using precision CMOS matrix allows scanner to receive a high quality fingerprint image. The scanner can be used in any application where effective and trustworthy person identification is required. A special LFD* electronic circuit is built in the scanner. This circuit allows a live finger to be distinguished from a model.

Main technical characteristics

Interface
USB 1.1
Operating surface resolution
508 dpi
Dimensions of scanning operating surface
16x24 mm
Dimensions of the scanned image
480х320 mm
Operating temperature
0°С ~ +55 °С
Power supply through USB port
DC 4.45.25
Weight
80 g
Data transfer rate
6 Mbit/sec

Interface converter (IC) USB-RS48

 

Purpose of use

The converter is intended for RS485 interface conversion into USB and provides data exchange between a control computer and BioSmart controllers. After module is linked up with the USB port of a personal computer virtual COM port is created.

Main technical characteristics

Interface
RS485
Rate of exchange
9600, 38400, 57600, 115200 bit/sec
Power supply
through USB port
Maximum demand

100 mА

Galvanic isolation
1500 V
Receive/ transmit mode indication

yes

USB data base
1.1 or 2.0

Interface converter (IC) LAN-RS485

 

Purpose of use

The converter is intended for RS485 interface conversion into Ethernet and provides data exchange between a control computer and BioSmart controllers.

Main technical characteristics

Interface
RS485
Transfer/receive rate

9600, 38400, 57600, 115200 bit/sec

Supported protocols

TCP/IP, UDP, ICMP, ARP, DLC, MAC

LAN speed

10/100 Mbit/sec

Power supply
12 V
Maximum demand
100 mA
RS485 galvanic isolation
yes
LAN galvanic isolation
yes
Receive/ transmit mode indication
yes

Interface converter (IC) GPRS-RS485

Преобразователь интерфейса (ПИ) GPRS-RS485 

Purpose of use

The converter is intended for duplex sequential batch dataflow transfer through GPRS and GSM communication channels.
  • Choice of communication GSM/GPRS channel is set by a user.
  • Working capabilities with dynamic IP addresses.
  • Fully "transparent" communication channel for the data terminal equipment.
  • "One-To-One and "One-To-Many" communication.
Versions:
  1. Plastic case without a power supply unit.
  2. Metallic case with a power supply unit and accumulator.

Main technical characteristics

Interface 
RS485
Power supply

5±0,25 V

Current consumption

500 mA

LED indication

2

Operating temperature
-30°С ~ +50°С
Dimensions
65х72х10 mm (35 mm with case)

BioSmart Relay control unit (RCU)

Purpose of use

The control unit is intended for execution units' (locks, turnstile and swing gate) control. Provides connection with external sensors of fire alarm systems. The control unit is conducted by commands of BioSmart controller through RS485 communication line. Up to four controllers can be connected to Biosmart RCU.

Main technical characteristics

Interface
RS485
Power supply

12 V

Peak current (without taking into account execution units)

150 mA

Digital relay outputs

2

Digital inputs (dry contact)

2

Max. quantity of BioSmart modules

4

Receive/ transmit mode indication

yes

Блок управления реле BioSmart

Examples of BioSmart Relay control unit application


BioSmart-Studio software

Purpose of use

BioSmart Studio software is bundled together with access control system BioSmart (for free). It allows you to configure and launch access control system BioSmart, register employees, set rights of access to employees, assign access time for every employee, display doors' state and personal data of each employee during identification. For security officer or front-door security it is possible to adjust BioSmart-Studio software in real time monitoring mode with appropriate events scanning and also for remote doors control, for example for visitors admission.

Main functions

  • database management;
  • registration of employees or groups of employees in the system;
  • employees' database maintenance (electronic filing);
  • time access appointment;
  • access rights appointment;
  • events monitoring;
  • log book forming;
  • symbolic circuit (building plan);
  • system configuration and adjustment;
  • executive devices management in monitoring mode.

BioSmart-WorkTime add-on module

Purpose of use

BioSmart-WorkTime software disposes comprehensive facilities on generation and adjustment of appropriate reports (statistics of facilities access, statistics of employees' passes/movement, working time sheet with different level of details, report of operating schedule violations and violators and etc.). It is possible to create reports both on the exact employee or facility and group of employees or facilities for the exact period of time. It is possible to create a reporting form manually by means of the master of report. Flexible import/export allows data exchange with another administrative software. All kinds of reports can be easily exported to Microsoft Excel for further processing. The module is activated with a special USB key.

Main functions

  • working time sheet T-13 format;
  • arrival report;
  • leaving report;
  • late arrival report;
  • early leaving report;
  • working time detailed report;
  • attendance report;
  • absence reason input possibility;
  • export in Microsoft Excel.

Examples of reports

Example of WorkTime application with BioSmart controller Example of WorkTime application with biometric scanner FS-80

BioSmart - NetWork add-on module

Purpose of use

BioSmart-NetWork software allows BioSmart-Studio software to be arranged in the regime of Client-Server network connection for two or more working places. Connection is carried out through local Ethernet 10/100 Mbit. It is activated by the special USB key.

Main functions

  • system administration from a remote office;
  • events monitoring from a remote office;
  • receiving of working time reports at a remote office;
  • differentiation of rights of access to BioSmart-Studio software applications.

INTEGRATION

Pic. Example of Wiegand interface exit usage

For integration with other manufacturer's devices BioSmart controller card has Wiegand interface input and output working in the range of 26 to 40 bit.

The Wiegand interface output allows BioSmart controllers to be integrated in any control and access control system. In case of successful fingerprint identification BioSmart controller transfers the code similar to the card code to the controller of off-site monitoring and access control system. By-turn access control system controller decides about right of access and signals to an execution unit. Thus the charges for replacement of existing card system to the biometric one are greatly reduced. It is enough to replace only readers while controller, employees database, execution units and cable paths rest the same.

The Wiegand interface input allows you to connect proximity card reader or dialing panel to BioSmart controller. Such a mode can be used for two-factor identification in controlled-access facilities or for lock regime arrangement, i.e. at first a user has to apply the card or input the password and then apply a finger to the BioSmart controller. The most widespread solution is arrangement of visitors' access by cards while employees use fingerprints. There is a possibility of integration with burglar alarm.

Pic. The example of Wiegand interface output application